Wavecontrol WP50 E-H Field Probe (10Hz - 3kHz, 20000 V/m , 2000 µT)

ModelWP50
OriginSpain
Warranty12 months
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Main applications: Energy, Induction heating, Electric arc or induction smelting. Workplace assessment, Human exposure assessment, Other low frequency applications
Frequency range: 10 Hz - 3 kHz
Sensor type: Isotropic, RMS, Combined measurement of electric and magnetic field
Type of frequency response:
1) Weighted (Results displayed in % of the selected standard)
2) Flat response (results inV/m, uT, etc.)
Exposure limits (probe in weighted mode): Public and occupational ICNIRP 2010; Customizable to other standards
Measurement range:
-Weighted mode (ICNIRP 2010):
+E-field: 0.025 % - 200 % of limit (RMS value)
+H-field: 0.025 % - 200 % of limit (RMS value)
-Field Strength Mode:
+E field: 2.5 V/m - 20000 V/m (RMS)
+H field: 0.25 µT - 2000 µT (RMS)
Dynamic range: 78 dB
Sensitivity:
-Weighted (E,H) 0.025 %
-Flat response E field 2.5 V/m
-Flat response H field 0.25 µT
Frequency response:
± 20 % (typ.) of standard
(25 Hz - 1 kHz)
± 25 % (max.)
Linearity: ± 1 % (typ.) (1 % - 100 % of stand); ± 2 % (max.)
Isotropic response: ± 5 % (typ.)
Calibration: ISO 17025 Accredited Calibration (ILAC)
Calibration period: 24 meses (recomendado)
Operating temperature: - 15 ºC a 50 ºC
Dimensions: 270 mm x 115 mm Ø
Field sensor area: 100 cm2
Weight: 210 g

Compatible with SMP2, MonitEM