For full functionality of this site it is necessary to enable JavaScript.
EMIN.MY
0
Product image

UNI-T UTS3021B Spectrum Analyzer (2.1GHz, 1Hz~3 MHz,-161dBm/Hz)

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Frequency range:9 kHz-2.1 GHz

Frequency resolution: 1Hz

Sweep width range: 0Hz, 100Hz~2.1GHz

Sweep accuracy: ± Sweep width /(Scanning points -1)

Cursor frequency uncertainty: ± [Cursor frequency reading × reference frequency accuracy + 1% × sweep width + 10% × resolution bandwidth + cursor frequency resolution]

Cursor type: General, difference, difference pair, relative

Cursor function: Noise, N dB bandwidth

RBW (-3 dB): 1 Hz~3 MHz, 1-3-10 stepping

Shape factor of resolution filter:<4.8:1(60dB:3dB), Gaussian like type

Video bandwidth (-3 dB): 1 Hz ~3 MHz, 1-3-10 stepping

Bandwidth uncertainty: < 5%

Amplitude measurement range (preamplifier off): DANL ~ +10 dBm, 100 kHz~1 MHz,

DANL ~ +20 dBm, 1 MHz~2.1 GHz

Reference level: -100 dBm ~ +30 dBm, Step 1 dB

Maximum input DC voltage: +/- 50 V DC

Maximum continuous wave RF power: 33 dBm, 3 minute, Input attenuation >20 dB

Display logarithmic level coordinates: 10 dB~100 dB

Display linear level coordinates: 0 ~Reference level

Level coordinate unit: dBm, dBmV, dBuV, V, W

Scanning points: 40001

Number of traces: 6

Detection mode: Positive peak, negative peak, sample, Normal, average (voltage / RMS / video), quasi peak

Trace function: Clear write, max hold, min hold, view, close, average

Frequency response: Preamplifier off: ±0.8 dB; ±0.4 dB, typ

Preamplifier on: ±0.9 dB; ±0.5 dB, typ

RBW switching error: ± 0.2 dB logarithmic resolution and ± 0.01 linear resolution relative to RBW at 10 kHz, nominal value

Input attenuation error: ±0.5 dB(20℃ ~30℃, fc=50 MHz, Preamplifier off, Attenuation relative to 20 dB, Input attenuation 1~51 dB )

Absolute amplitude accuracy: Preamplifier off: ±0.4 dB, Input signal level -20dBm (20℃ ~30℃, fc=50 MHz, RBW=1 kHz, VBW=1 kHz, peak detector, attenuation input 20 dB)

Preamplifier on: ±0.5 dB, Input signal level -40dBm (20℃ ~30℃, fc=50 MHz, RBW=1 kHz, VBW=1 kHz, peak detector, attenuation input 20 dB)

Full amplitude accuracy: ±0.7 dB(20℃ ~30℃, Fc>100 kHz, Input signal level -50 dBm~0 dBm, RBW=1 kHz, VBW=1 kHz, Peak detection, Input attenuation 20dB, Preamplifier off, 95% Confidence)

Voltage input standing wave ratio: Input attenuation 10 dB

1 MHz~2.1 GHz <1.5, Nominal value

Scanning time: 1 ms ~ 4000 s

Scanning mode: Sweep frequency, FFT

Scan rule: Continuous, single

Trigger source: Free, video, external

External trigger settings: level(5V TTL), Rising edge / falling edge

Tracking source:

- Frequency range: 100 kHz~2.1 GHz

- RBW: 30 Hz~1 MHz, Only scan mode is supported

- Output level range: -20 dBm~0 dBm

- Output level resolution: 1 dB

- Flatness output: +/-3 dB

- Maximum reverse input level: Average power: 30 dBm, DC : ±50 V DC

Interface: Trace source output,10MHz reference input, 10MHz reference output,Ext Trigger,HDMI,USB host, USB device,LAN, 3.5mm

Power: 100~240V AC, 50Hz/60Hz

Display: 10.1 inch TFT LCD (1280x800) touch

Product size (W×H×D): 368 mm×218 mm×120 mm

Product net weight: 4.5kg


Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts