For full functionality of this site it is necessary to enable JavaScript.
EMIN.MY
0
Product image

Tinsley 5903N Long-Haul Submarine Cable Test Set

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Operational Modes: Cable Test, Resistance, Capacitance, IR Impedance, No Loss of Current Kennelly’s Two & Three Current Test, Schaefer Test Method, Open Circuit Short Circuit, Fixed Load, Power Feeding.

Input Requirements: 3 Phase 20 Amps, Sea Earth, System Safety Earth

Power Output Options:

Single Module 10Kv, at Max 1.2 Amps 20Kv at Max 0.6 Amps

Dual Module 10Kv at Max 2.4 Amps 20Kv at Max 1.2 Amps

Triple Module 10Kv at Max 3.6 Amps 20Kv at Max 1.8 Amps

Resistance measurement in ranges:

1-9.9R

10 to 99.9R

100 to 999.9R

1K to 10K

10K to 100K

Resistance Accuracy: 1%

Capacitance Measurement:

0 to 1uF

1 to 10uF

10 to 100uf

100 to 1mF

1mF to 10mF

10mF to 100mF

Capacitance Accuracy: 2%

Insulation Resistance: 10x104 to 10x107

Voltage Measurement: 10v to 20Kv

Current Measurement: 10uA to 3.6A

Single Unit Variant Size: 19” Wide, 82cm Deep, 160cm Weight: 95kgs for single Unit

Dual Unit Variant Size: 19” Wide, 82cm Deep, 160cm Weight: 115kgs

Triple Unit Variant: TBA

* Subject to change without notification.

Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts