Resolution 8 bit @1MΩ: 1mV*~10V

*: When the vertical scale is set to 1mV/div, the bandwidth limit will be set

to 20MHz automatically.

Input Coupling AC, DC, GND

Input Impedance 1MΩ // 16pF

DC Gain Accuracy* ± (5% × |Readout| + 0.1div + 1mV) when 1mV/div is selected

±(3% × |Readout| + 0.1div + 1mV) when 2mV/div or greater is selected

*: The measurement type is average of ≥ 16 waveforms with the vertical

position at zero

Polarity Normal & Invert

Maximum Input Voltage 300V (DC+AC Peak), CAT I

Oset Position Range 1mV/div ~ 20mV/div: ±0.5V

50mV/div ~ 200mV/div: ±5V

500mV/div ~ 2V/div: ±25V

5V/div ~ 10V/div: ±250V

Waveform Signal Process +, -, ×, ÷, FFT, FFTrms, d/dt, ∫dt, √

FFT:Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS,

and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris.

Trigger

Source CH1 ,CH2, CH3, CH4, Line, EXT, D0-D15

Trigger Mode Auto (supports Roll Mode for 100 ms/div and slower), Normal, Single

Trigger Type Edge, Pulse Width, Video, Pulse Runt, Rise & Fall, Timeout, Alternate, EventDelay(1~65535 events), Time-Delay(10nS~10S), Logic*, Bus**with Logic

Analyzer Option

Holdo range 10nS to 10S

Coupling AC,DC,LF rej. ,Hf rej. ,Noise rej.

Sensitivity DC ~ 100MHzApprox. 1div or 1.0mV

100MHz ~ 200MHzApprox. 1.5div or 15mV

200MHz ~ 300MHzApprox. 2div or 20mV

External Trigger

Range ±15V

Sensitivity DC ~ 100MHzApprox. 100mV

100MHz ~ 200MHzApprox. 150mV

200MHz ~ 300MHzApprox. 150mV

Input Impedance 1MΩ// 16pF

Horizontal

Time base Range 1ns/div ~ 100s/div (1-2-5 increments)  ROLL: 100ms/div ~ 100s/div

Pre-trigger 10 div maximum

Post-trigger 1000 div maximum.

Accuracy ±20 ppm over any ≥ 1 ms time interval

Real Time Sample Rate 1CH: 2GSa/s 2CH: 1GSa/s

ET Sample Rate 100GSa/s maximum

Record Length 1CH: 2Mpts(10div)  2CH: 1Mpts(10div)

Acquisition Mode Normal, Average, Peak Detect, Single

Peak Detection 2nS (typical)

Average Selectable from 2 to 256

X-Y Mode

X-Axis Input Channel 1; Channel 3*

Y-Axis Input Channel 2; Channel 4*

Phase Shift ±3° at 100kHz

Cursors and Measurement

Cursors Amplitude, Time, Gating available

Automatic Measurement 36 sets: Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS,

Cycle RMS, Area, Cycle Area, ROVShoot, FOVShoot, RPREShoot, FPREShoot,

Frequency, Period, RiseTime, FallTime, +Width, -Width, Duty Cycle, +Pulses,

-Pulses, +Edges, -Edges, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF, Phase

Cursors measurement Voltage dierence between cursors ( ∆V)

Time dierence between cursors ( ∆T)

Auto counter 6 digits, range from 2Hz minimum to the rated bandwidth

Multi-language menu Available

Time clock Time and Date ,Provide the Date/Time for saved data

Dimensions 380mmX220mmX145mm

Weight 4.2kg

Accessory AC Power cordx1, Probe x4 or x2, ACCESSORY CD-ROMx1, USING THE

PRODUCT SAFTYx1

Download datasheet


Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts