Sundy SDTGA6000A Thermogravimetric Analyzer (RT~1000℃, 4kW)

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Test index: Moisture, ash ,volatile matter and LOI

Continuous test in batches: Yes

Standards: ISO 17246, ISO 18123/18122/18134, ISO 11722, ISO 1171,ASTM D3173/D3174/D3175/D7582, GB/T 30732, GB/T 212

Precision: 0.02% RSD

Furnace temperature: Room temperature~1000℃

Temperature control precision: ±2℃

Temperature resolution: 0.1℃

Reproducibility: Ash: 0.30% (<15.00%); 0.50% (15.00~30.00%); 0.70% (>30.00%)Volatile matter: 0.50% (<20.00%); 1.00% (20.00~40.00%); 1.50% (>40.00%)

Cooling time required for batches of test: No

Furnace Cooling (forced air/N2): 950 to 500°C<30 min

Balance Resolution: 0.0001g

Sample introduction and taking: Automatic

Max. Samples: 19 samples + 1 blank sample position

Quantity of sample / test time:: Full indexes for 19 samples< 120 min (Quick method)

Sample weight: 0.5 up to 5g

Max. power: 4kW

Interface:: RS232

Furnace Heating: Resistance Wound

Temperature Calibration: Standard thermocouple

Temp. control precision: ±2℃ (moisture) ±5℃ (ash, volatile matter)

Gas Flow Rate: GB:Moisture:Nitrogen,30~60 times/h Ash:Air 60~120 times/h ASTM:Moisture:Nitrogen or Air 2~4(Furnace Volume /min)volatile matter:Nitrogen 2~4(Furnace Volume /min)

Power requirement: AC 220 V(±10%),50 / 60Hz

Gas requirement: Nitrogen/Oxygen/Compressed Air

Gas Pressure: Air 5 to 6 bar (75 to 90 psi)

Minimum Gas Purity: Air/Nitrogen/Oxygen 99.5%; dry, oil-free

Sample weighing: Under normal temp.

Test Temperature: Moisture 105℃,Ash 815℃,Volatile matter 920℃~950℃ Can be customized

Humidity: <80%

Dimensions: 550x590x530mm

Weight: 70kg

Operational Control: Windows®-based software on external PC/Windows7/ WindowsXP

Advance Calculation: Yes

Analysis Report: Yes

Statistics Report: Yes

System Monitor: Yes

19 samples can be loaded once + 1 blank sample position for analyzing the moisture, ash and volatile matter.

Unique sample weighing mode, single sample or batch sample weighing are both available, makes the operation convenient.

Automatic temperature calibration function is available.

Flexible software design, test procedure, analysis time, temperature etc. can be customized.

LED displays on furnaces to show real-time balance weight data, it makes the sample weighing more convenient.

Single and dual furnace configurations available.