Specifications

pH:

Measuring range: (-2.00 ~ 18.00) pH

Resolution: 0.1/0.01 pH

Accuracy: ±0.02 pH

Input current: ≤2×10^-12 A

Input impedance: ≥1×10^12 Ω

Stability: ±0.01 pH/3h

Temp compensation: (0 ~ 100)℃ (auto or manual )

mV:

Measuring range(mV/ORP/EH): -1999.9mV ~ 0 ~ 1999.9mV

Resolution: 1mV

Accuracy: ±0.1% FS

Conductivity:

Measuring range: Conductivity

(0.00~20.00) μS/cm (20.0~200.0) μS/cm

(200~2000)μS/cm (2.00~20.00) mS/cm

(20.0~200.0)mS/cm

(200~2000) mS/cm (K=10)

Resistivity: (0 ~ 100) MΩ·cm

TDS: (0 ~ 100) g/L

Salinity: (0 ~ 100) ppt

Resolution: 0.01/0.1/1μS/cm 0.01/0.1/1 mS/cm

Accuracy: Electrode: ±0.5% FS, Instruments: ±0.80%FS

Temp compensation: (0 ~ 100)℃ (automatic)

Electrode constants: 0.1/1/10 cm^-1

Reference temperature: 25℃, 20℃,18℃

Dissolved Oxygen

Measuring range: (0 ~ 20.00)mg/L(ppm) (0 ~ 200.0)%

Resolution: 0.1/0.01 mg/L(ppm) 1/0.1 %

Accuracy: Electrode: ±0.10 mg/L, Instrument: ±0.40 mg/L

Response time: ≤30s (25℃, 90%response)

Residual current: ≤0.1 mg/L

Temp compensation: (0 ~ 100)℃ (automatic)

Salinity compensation: (0 ~ 45) ppt (automatic)

Pressure compensation: (80 ~ 105) kPa (automatic)

Automatic calibration: Air saturated by water, water saturated by air

Electrode type: Polarographic

Temperature:

Measuring range: 0℃~ 100℃

Resolution: 0.1℃

Accuracy: 5~ 60℃: ±0.4℃ Others: ±0.8℃

Other Parameters:

Data storage: 500groups

Power requirements: DC12V/1A

Communications: USB, Wireless Bluetooth

Dimensions & Weight: 270×170×70mm/600g

Working Conditions:

Ambient temperature: 5 ~ 35℃

Ambient humidity: ≤85%

IP grade: IP54

Standard Configuration:

1. S-630 benchtop multi-parameter analyzer: 1 unit

2. Composite pH electrode: 1 pc

3. Rotary electrode holder: 1 pc

4. pH calibration buffer: 1 set

5. Conductivity electrode: 1 pc

6. DO Electrode: 1 pc

7. DO membrane cap: 3 pcs

8. DO electrode electrolyte (30mL): 1 bottle

9. 12V power adapter: 1 pc

10. Instruction manual: 1 copy

Datasheet

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.