Size Range: 0.3 to 25 μm

Size Channels: Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm

Flow rates : 1.2 LPM ±3%

Concentration Limits: 15,000,000 particles/ft3 @ 10% coincidence (per ISO 21501-4), 30,000,000 particles/ft3 @ 10% coincidence (as tested and validated1)

Aerosol Concentration Range: 0.01 to 20,000 μg/m³

Light Source: Long life laser diode

Resolution: 0.00003 μg/m3

Zero Stability: No appreciable drift

Count Modes: Particles/second, Real-Time Meter, cumulative/diff. (count/m³ and count/ft³) and mass concentration (PM)

Log Interval: 1 second to 99 hours

Calibration: NIST traceable

Display: Enclosed 4.3″ (10.9 cm) WQVGA (480×272) color touch screen

Vacuum Source: Internal pump with automatic flow control

Filtered Exhaust: Internal HEPA filter

Number of Channels: 6

Custom Size Channels: Calibration for custom size channels available

Communication Options: Ethernet, USB, RS485 or RS232

Environmental Sensor: Temperature and relative humidity probe: -4º to 122ºF (-20º to 50ºC) ±1ºF (0.5ºC), 0 -100% ± 2%RH

Optional Sensors: NDIR CO2 (0-5000 ppm, resolution 1 ppm, accuracy ±1% FS, Response rate 20 seconds) TVOC PID, 0-50 ppm / min. detection level 5 ppb, accuracy ±1.5%, Response rate <3 seconds

Alarm: Alarms for all particle values, environmental sensors, flow and sensor failure

Calibration: Particle sensor recommended once per year

User Calibration: Field Calibration of Temperature, Humidity, CO2 and TVOC possible with included utility software

External Surface: ULTRAGUARD® Fiberglass reinforced polyester - compression molded SMC box and Cover

Dimensions (L x W x H): 12.85 x 7.41 x 25.54 in (32.7 x 18.9 x 64.9 cm) includes barb fittings

Weight: 12.5 lbs. (5.66 kg)

Accessories: Quick start guide, operating manual on USB flash drive, mounting feet

Optional Accessories: Printed manual, data cable, pole mounting hardware kit

Data Storage: Internal 45,000 sample records (rotating buffer) including particle count data and environmental data

Power: 110 to 240 VAC 50/60 Hz universal in-line power supply

Operating Conditions: -4º to 122ºF (-20º to 50ºC) / 20% to 95% non-condensing