For full functionality of this site it is necessary to enable JavaScript.
EMIN.MY
0
Product image

OMEGA PX409-1.0KDDU10V High Accuracy oil filled Wet/Dry and Wet/Wet Differential Pressure Transducers (Differential, 1000 psi, NPT Male, 1/4 in)

ModelPX409-1.0KDDU10V
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Shock: 50 g, 11 ms half-sine

Weight: 200 g

Accuracy: ± 0.08 %

Bandwidth: DC to 1 kHz

Stability: ± 0.1%

Vibration: 5-2000-5 Hz, 30 minute cycle,Curve L, Mil-Spec 810 figure 514-2-2, vertical and horizontal axis

Cable Length: 2 m

Current Draw: 10 mA

Accuracy Note: 0.08% BSL linearity, hysteresis and repeatability combined Thermal Accuracy: ± 0.50%(Span &Zero)

Output Signal: Voltage

Pressure Type: Differential

Pressure, Max: 1000 psi

Pressure, Min: 0 psi

Response Time: <1 ms

Accuracy Class: < 0.1%

Proof Pressure: 3x Full Scale up to 3000 psi

Stability Note: Long Term Stability (1-Year): ± 0.1% FS typical

Supply Voltage: 15 to 30 Vdc

Pressure Cycles: 1 million, minimum

Electrical Output: 0 to 10 V

Materials, Wetted: 316L Stainless Steel

Output Resistance: 2500 Ω

Supply Power Note: Max Current Output: 2 mA

Zero/Balance Error: ± 0.5%

Media Compatibility: Air, Alkaline solutions, Any, Argon, Carbon dioxide, Dilute Acids, Gases, Helium, Hydraulic Oil, Hydrogen, Light Oil, Liquids, Nitrogen, Non-corrosive Dry Gasses, Oil, Oxygen, Solvents, Steam, Water, Water-based fluids

Proof Pressure Note: 3 times range

Line/Static Pressure: 500 psi max

Additional Features 1: None

Electrical Connection: Cable

Insulation Resistance: 100 MΩ

Process Connection Size: 1/4 in

Process Connection Type: NPT Male

Zero/Balance Error Note: ± 0.5% typical (1% maximum)

Operating Temperature, Max: 121 °C

Operating Temperature, Min: -45 °C

Compensated Temperature, Max: 85 °C

Compensated Temperature, Min: -29 °C

Span Setting Adjustable Range: ± 0.5% typical (1% maximum)

Positive Side differential wetted materials: 316L stainless steel

Negative Side differentional compatable fluids or gasses: Clean, Dry, Non-ionic gases

Datasheet


Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts