For full functionality of this site it is necessary to enable JavaScript.
EMIN.MY
0
Product image

OMEGA DP41-U-230-S2 1/8 DIN High Performance Temperature, Process and Strain Meter (Universal Input Indicator, 6 Digit Single LED, 230 Vac)

ModelDP41-U-230-S2
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Width: 96 mm

Height: 48 mm

Length: 165 mm

Weight: 574 g

Accuracy: ± 0.005 %

Polarity: Unipolar/Bipolar, programmable

Setpoint: 4 isolated open collector; rated 150 mA at 1V sink, 30V open

Input Type: Universal Input Indicator

Resolution: 15-bit

Form factor: 1/8 DIN

Display Size: 13.7 mm (0.54 in)

Display Type: 6 Digit Single LED

Reading Rate: 3/s or 13/s, 60 Hz; 3/s or 12/s, 50 Hz

Display Color: Red, Green

Output Detail: Isolated, tri-state, TTL/CMOS compatible; external 5V supply required for isolated; internal 5V supply for non-isolated

Sampling Rate: 13 Hz (13 updates/second)

Step Response: 1 sec to 99.9%

A/D Conversion: Dual-slope technique

Control Output: None

Data Interface: RS232

Supply Voltage: 230 Vac

Input Type Note: Thermocouple, RTD, Analog Current/Volatge, Strain

Span Adjustment: 0.00001 to 500,000 counts, programmable

Number of Inputs: 1

Cutout Dimensions: 45 x 92 mm

Display Type Note: Red or green 6-digit, 14-segment, 13.7 mm (0.54") high; 4 alarm indicators

Enclosure Ratings: IP65, NEMA Type 4

Offset Adjustment: 0 to 999,999 or 0 to -99,999, programmable

Power Consumption: 10 W

Relative Humidity: 95% RH, non-condensing

Supply Power Note: 115 or 230 Vac, 49 to 400 Hz; 10 to 32 Vdc

Supply Power Type: AC

Common Mode Voltage: 1500 Vp per HV test

Data Interface Note: 300/600/1200/2400/4800/9600/ 19.2K baud; RJ11 4-wire connection; programmable to transmit current display, alarm status, min/max, actual measured input value and status

Input Configuration: Single-ended

Thermal Span Effect: ±20 ppm

Common Mode Rejection: 120 dB

Normal Mode Rejection: 60 dB

Output Configurations: None

Power Consumption Note: 6 W nom., 10 W max

Sensor Break Protection: Up-scale or down-scale, programmable

Sensor/Transmitter Power: 10 V at 30 mA; 24V at 25 mA

Storage Temperature, Max: 85 °C

Storage Temperature, Min: -40 °C

Current Measurement Range: 0 to 20 mA, 4 to 20 mA

Voltage Measurement Range: 0 to 100 mV, 0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, 0 to 100V, ±50 mV, ±500 mV, ±5V, ±50V

Warm-Up to Rated Accuracy: 50 min

Operating Temperature, Max: 50 °C

Operating Temperature, Min: 0 °C

Output Configurations Note: None

Temperature Measurement Range: Type J: -210 to 760°C,Type K: -270 to 1372°C,Type T: -270 to 400°C,Type E: -270 to 1000°C,Type R/S: -50 to 1300°C,Type B: 100 to 1820°C,Type N: -270 to 1300°C,Type J DIN: -200 to 900°C,RTD 1: -200 to 200°C,RTD 2: -200 to 900°C,RTD 3: -200 to 850°C

Datasheet


Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support