Oceanus OC-F08 CH4 Fixed Gases Detector (0 ~ 10%vol; IR sensor)

ModelOC-F08 CH4
P/NOC-F08CH40~10%vol,IR sensor
OriginChina
Warranty12 months
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Applicable Gas: CH4

Model: OC-F08 CH4 (0~10%vol)

Detecting Range: 0~10%vol

Sampling: Diffusion or pump-suction, circulation selectable

Accuracy: ≤±3%F.S

Repeatability: ≤±1%

Zero drift: ≤±1%(F.S/year)

Sensor Type: Infrared sensor

Sensor Life: 2~3 years

Response Time: (T90) ≤20s

Alarming mode: Audible-visual alarm(Optional)

Operating Environment

Temperature: -30℃~60℃ (Customized for special demands)

Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter

Pressure: 86kPa~106kPa

Working Voltage: 24V DC(16~30VDC)

Output Signals

(Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc;

(Optional) Four-wire system RS485 digital signal output;

(Optional) Frequency signal 200~1000Hz output;

Two-level relay output: 220VAC 0.5A, 5VDC 0.5A

Installation Means: Wall mounted, Pipe type(Thread:M40*1.5 )

Material of Body: Cast aluminum

Explosion-proof Index: Ex d IIC T6

Protection Grade: IP66

Electrical Interface: 3/4″NPT(Female Screw)、1/2″NPT(Female Screw)

Transmit Distance: ≤2000m

Dimension: 210 mm×140 mm×92 mm(L×W×H)

Weight: About 1.5Kg

Standards: GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010

Option: For other measuring ranges please see datasheet or Contact us to customize the suitable one.

OC -F08 datasheet 

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts