For full functionality of this site it is necessary to enable JavaScript.
EMIN.MY
0
Product image

MILWAUKEE MW170 EC/TDS/NaCl/Temp bench meter (EC: ~500 mS/cm; TDS: ~400 g/L; NaCL: ~80.00 g/L)

ModelMW170
OriginRumani
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

EC Range: 0.00 to 29.99 µS/cm / 30.0 to 299.9 µS/cm

EC Range: 300 to 2999 µS/cm

EC Range: 3.00 to 29.99 mS/cm / 30.0 to 200.0 mS/cm

EC Range: up to 500 mS/cm absolute conductivity**

TDS Range: 0.00 to 14.99 ppm (mg/L)

TDS Range: 15.0 to 149.9 ppm (mg/L) / 150 to 1499 ppm (mg/L)

TDS Range: 1.50 to 14.99 g/L / 15.0 to 100.0 g/l

TDS Range: upt to 250.0 g/L absolute TDS**

TDS Range: up to 400 g/L absolute TDS** (with 0.80 factor)

Salinity Range: 0.0 to 400.0% NaCl / 2.00 to 42.00 PSU

Salinity Range: 0.00 to 80.00 g/L

Temp. Range: -20.0 to 120.00°C (-4.0 to 248.0°F)

EC Resolution: 0.01 uS/cm / 0.1 uS/cm / 1 uS/cm

EC Resolution: 0.01 mS/cm / 0.1 mS/cm

TDS Resolution: 0.01 ppm / 0.1 ppm / 1 ppm

TDS Resolution: 0.01 g/L / 0.1 g/L

Salinity Resolution: 0.1% NaCl / 0.01 PSU / 0.01 g/L

Temperature Resolution: 0.1°C / 0.1°F)

Accuracy @ 25°C / 77°F

EC: ± 1% of reading / ±0.05 uS/cm or 1 digit, whichever is greater

TDS: ±1% of reading / ±0.03 ppm or 1 digit, whichever is greater

Salinity: ±1% of reading

Temperature: ±0.5°C (±0.9°F)

Calibration

EC/TDS: single cell factor calibration, 6 standards: 84 uS/cm, 1413 uS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm / one point offset: 0.00 uS/cm

Salinity: one point with MA9066 salinity calibration solution

Temperature Compensation: Automatic or manual from -20 to 120°C (-4.0 to 248.0°F) or NO TC without temperature compensation

Conductivity temperature coefficient: 0.00 to 6.00 % / °C (EC and TDS only) | Default value: 1.90 % / °C

TDS factor: 0.40 to 0.80 / Default value: 0.50

EC Probe: MA814DB/1 4 ring

Temperature probe: Built-in temperature sensor

Logging: Maximum 1,000 log records (stored in up to 100 lots) / on demand, 200 logs on stability, 200 logs, interval logging 1000

PC Connectivity: 1 micro USB port

Power Supply: 12 VDC adapter (included)

Battery Type: Internal

Battery life: Approx. 8 hours of use

Environment: 0 to 50°C / 32 to 122°F; max RH 95%

Dimensions: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)

Weight: 0.9 kg / 2.00 lbs.

** Absolute conductivity (or TDS) is the conductivity value without temperature compensation spare probe & calibartion

Manual

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts