Weight: 4.5 kg (10 lbs)

Outputs: 4 Analog

Humidity: 10-90% non-condensing

Flow Rate: 40 mL/min – 60 mL/min

Sample pH: 2.5-12

Update Rate: Once per second

Power Supply: 100-240 VAC, 50-60 Hz, 25 W, on power loss all settings are retained without batteries

Analog Output: 22mA alarm, 500 ohm max load, not for use with externally powered circuit For sodium, conditioned pH, temperature four powered 0/4-20 mA,

EnclosureType: Full

Response Time: 90% at 5 minutes

Relay Contacts: 3A resistive freely assignable to setpoints for sodium, pH, temperature other relays used for auto-cal

Operating Range: 0.01 ppb – 100,000 ppb

Sample Pressure: 0.3-7 bar (5-100 psig)

Sample Flow rate: >40 mL/min (>20 mL/min for cation exchange samples), excess to drain

Ratings/Approvals: CE, UL, IP65

Built-in sequencer: No

Dimensions (HxWxD): 851 mm x 400 mm x 165 mm

Operator Interface: 4-line backlit LCD, 5 tactile keys simultaneous display of sodium, conditioned pH, auto-cal status (temperature optional)

Process Connection: Drain Hose: 19x25.4 mm (3/4 x 1") 2 m (6 ft) length included Sample inlet: 6 mm or 1/4" OD tube SS compression fitting Drain hose: 19 x 25.4 mm (¾ x 1"), 2 m (6 ft) length included

Sample Temperature: 5-50°C (41-122°F)

Sodium Calibration: Manual 3-point known addition manual 1- or 2-point

Reagent Consumption: 3-4 L per year DIPA, or 9-12 L per year ammonium hydroxide typical more at higher temperatures and for cation exchange samples

Power Supply (AC/DC): 100 V – 240 V

Analog Output Scaling: Linear, bi-linear, logarithmic (1,2,3,4 decades), auto ranging

Measurement Parameter: Sodium

Analog Output Accuracy: ± 0.05 mA

Electrode Conditioning: Manual

Grab Sample Measurement: Available option

Operating Range (Temp.): 5 °C – 50 °C

Sodium Measurement Range: 0.01-100,000 ppb or equivalent ppm, auto-ranging

Sodium Measurement Accuracy: ± 10% of reading ± 0.1 ppb, typical using DIPA as reagent ± 10% of reading ± 1 ppb, typical using ammonium hydroxide as reagent

Ambient Operating Temperature: 5-50 °C (41-122 °F)