Nominal input voltage: 200 Vac to 240 Vac, 47 Hz to 63 Hz

Output power: 1206 W

Output voltage: ± 60V

Output current: ± 20.1 A

1- Constant voltage (CV mode)

*DC Voltage:

Setting range: 0 V to ± (105 % of rating), 0 V to + (105 % of rating)

Setting accuracy: ± (0.05 % of setting + 0.05 % of rating)

*AC voltage:

Setting range: 0.00 Vpp to (210 % of rating) pp

Setting accuracy: ± 0.3 % of rating

*AC frequency:

Setting range: 0.01 Hz to 100.00 kHz

Response: 3.5 μs, 10 μs, 35 μs, 100 μs

Ripple noise: 40 mV

Load effect: ±(0.005 % of setting + 1 mV)

Source effect: ± (0.005 % of setting + 1 mV

2- Constant current (CC mode)

*DC current:

Setting range: 0 A to ± (105 % of rating), 0 A to ± (105 % of rating)

Setting accuracy: ± 0.3 % of rating

*AC curent:

Setting range: 0A pp to (210 % of rating) p-p

Setting accuracy: ±0.5 % of rtg

*AC frequency:

Setting range: 0.01 Hz to 100.00 kHz

Response time: 35 μs, 100 μs, 350 μs, 1 ms

Ripple noise: 5 mA

Load effect: ±(0.01 % of setting + 1 mA)

Source effect: ±(0.01 % of setting + 1 mA)

3- Measurement display function

Measurement accuracy:

DCV : ± (0.05 % of reading + 0.05 % of rating)

ACV, ACV+DCV :

±(0.5 % of reading + 0.1 % of rating) tại 5 Hz ~ 10 kHz

±(1 % of reading + 0.2 % of rating) tại 10 kHz ~ 50 kHz

±(2 % of reading + 0.2 % of rating) tại 50 kHz ~ 100 kHz

DCA : ± (0.3 % of reading+ 0.7 % of rating)

ACA, ACA+DCA :

±(3 % of reading + 0.1 % of rating) (5 Hz ~ 10 kHz)

±(10 % of reading + 1 % of rating) (10 kHz ~ 100 kHz)

Protection functions: Overvoltage, Overcurrent, Overheat, Power limit

Control functions: I/O

Interface: RS232C, GPIB, USB & LAN

4- Waveform

Type: Sine wave, square wave, triangle wave, and 16 user-defined arbitrary waveforms

Start phase: 0 to 359°

Square wave duty cycle: 0.1 % to 99.9 % (f < 100 Hz), 1 % to 99 % (100 Hz ≤ f < 1 kHz), 10 % to 90 % (1 kHz ≤ f < 10 kHz), and fixed to 50 % (10 kHz ≤ f)