For full functionality of this site it is necessary to enable JavaScript.
EMIN.MY
0
Product image

KEISOKU GIKEN NT-AD-50KH-L AC/DC Regenerative Electronic Load (50kW; 750V; 200A)

USD 79,236.29
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Basic functions

Rating:

Rated power: 50kw

Rated voltage: 750V

Rated current: 200A

Minimum operating voltage: 0V

Ripple current: Within 4 Ap-p (switching frequency component)

Efficiency: Power regeneration efficiency: 90% (at full load)

Constant voltage (CV) mode: Voltage setting range: 0 to 750V

Constant current (CC) mode: Current setting range: 0 to 200A

Constant Resistance (CR) Mode: Current setting range: 0.1Ω to 3.00kΩ

Constant Power (CP) Mode: Power setting range: 0 to 50kw

MPPT mode: Mountain climbing method (factory option)

CC+CV mode: The setting range, resolution, and accuracy are based on CC mode and CV mode.

CP+CV mode: The setting range, resolution, and accuracy are based on CP mode and CV mode.

Soft Start: 0, 1, 2, 5, 10 sec


Measuring part

Voltage measurement: Voltage measurement range: 0.0 to 750.0V

Current measurement: Current measurement range: 0.0 to 200.0A

Power measurement: Power measurement range: 0 to 50kw


Limit function

Voltage limit: Voltage setting range: 0 to 760V

Current limit: Current setting range: 0 to 200A

Power limit: Power setting range: 0 to 50kw


Interface: LAN; RS-232C

Standard specifications

Power supply: Input Rating: Grid side: 3-phase 3-wire 400±40V, 50 Hz ±2 Hz or 60 Hz ±2 Hz

Overvoltage category II

Power factor: At maximum load: 0.9 or higher

Input power: No load: 800 VA or less

Input current:

At maximum load (at AC400V): 60 Arms

At maximum load (at AC360V): 73Arms

Recommended circuit breaker: AC 100A

Mass: Main unit only: Approximately 950kg or less

Size: Excluding protrusions: W600 × H1977.5 × D900mm

Cooling method: Forced air cooling by fan

Withstand voltage:

Input-Output: No abnormalities were observed when AC1800V was applied for 1 minute.

Input-FG section: No abnormalities were observed when AC1800V was applied for 1 minute.

Insulation resistance: Input-FG section: DC500 V, 30 MΩ or more

DC-only model

Industry-leading regenerative efficiency of over 90%

Capacity expansion by combining multiple units

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts