Basic functions

Rating:

Rated power: 50kw

Rated voltage: AC 350Vrms / DC 750V

Rated current: AC 175 Arms / DC 200A

Minimum operating voltage: AC 20Vrms / DC 20V

Ripple current: Within 4 Ap-p (switching frequency component)

Efficiency: Power regeneration efficiency: 90% (at full load)

Constant voltage (CV) mode (DC mode only)

Voltage setting range: DC 20-750V

Constant current (CC) mode: Current setting range: AC 0.0Arms~175Arms / DC 0.0A~200.0A

Constant Resistance (CR) Mode: Current setting range: AC 0.12Ω~1.40kω / DC 0.10Ω~3.00kω

Constant Power (CP) Mode: Power setting range: 0 to 50kw

MPPT mode (DC mode only): Mountain climbing method (factory option)

CC+CV mode (DC mode only): The setting range, resolution, and accuracy are based on CC mode and CV mode.

CP+CV mode (DC mode only): The setting range, resolution, and accuracy are based on CP mode and CV mode.

Soft Start: 0, 1, 2, 5, 10 sec


Measuring part

Voltage measurement: Voltage measurement range: 0.0 to 750.0V

Current measurement: Current measurement range: 0.0 to 300.0A

Peak current measurement: 0A to 220A

Active power measurement: Power measurement range: 0 to 50kw

Apparent power measurement: 0VA to 50kva

Power factor measurement: ±1.00

Frequency measurement: 40Hz to 70Hz

Interface: LAN; RS-232C


Power supply: Input Rating: Grid side: 3-phase 3-wire 400±40V, 50 Hz ±2 Hz or 60 Hz ±2 Hz

Overvoltage category II

Power factor: At maximum load: 0.9 or higher

Input power: No load: 800 VA or less

Input current: At maximum load (at AC400V): 60 Arms

At maximum load (at AC360V): 73Arms

Recommended circuit breaker: AC 100A

Mass: Main unit only: Approximately 750kg or less

Size: Excluding protrusions: W600 × H1977.5 × D900mm

Cooling method: Forced air cooling by fan

Withstand voltage: Input-Output: No abnormalities were observed when AC1800V was applied for 1 minute.

Input-FG section: No abnormalities were observed when AC1800V was applied for 1 minute.

Insulation resistance: Input-FG section: DC500 V, 30 MΩ or more

It can be used as both an AC and DC electronic load.

Industry-leading regenerative efficiency of over 90%

Individually, it can handle 50kW, and when connected in parallel, it can handle a maximum of 250kW.

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts