For full functionality of this site it is necessary to enable JavaScript.
EMIN.MY
0
Product image

Hanna HI9829-01042 Multiparameter - pH / ORP / EC / TDS / Salinity / DO / Turbidity / Temp - 4m

ModelHI9829-01042
Warranty12 months
USD 4,596.34
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Range

pH/mV of pH input:0.00 to 14.00 pH/±600.0 mV

ORP mV:±2000.0 mV

Ammonium- Nitrogen:0.02 to 200 ppm (as N)

Chloride:0.6 to 200 ppm

Nitrate-Nitrogen:0.62 to 200 ppm (as N)

Conductivity:0 to 200 mS/cm (absolute EC up to 400 mS/cm)

TDS:0 to 400000 mg/L or ppm (the maximum value depends on the TDS factor)

Resistivity:0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm

Salinity:0.00 to 70.00 PSU

Seawater σ:0 to 50.0 st, s0, s15

Turbidity:0.0 to 99.9 FNU; 100 to 1000 FNU

Dissolved Oxygen:0.0 to 500.0%; 0.00 to 50.00 ppm

Atm. Pressure:450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa

Temperature:-5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K

Resolution

pH/mV of pH input:0.01 pH / 0.1 mV

ORP mV:0.1 mV

Ammonium- Nitrogen:0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm

Chloride:0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm

Nitrate-Nitrogen:0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm

Conductivity:manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm

TDS:manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt); autorange scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); autorange g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)

Resistivity:dependent on resistivity reading

Salinity:0.01 PSU

Seawater σ:0.1 σt, σ0, σ15

Turbidity:0.1 FNU from 0.0 to 99.9 FNU; 1 FNU from 100 to 1000 FNU

Dissolved Oxygen:0.1%; 0.01 ppm

Atm. Pressure:0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

Temperature:0.01°C; 0.01°F; 0.01K

Accuracy @ 20°C

pH/mV of pH input:±0.02 pH / ±0.5 mV

ORP mV:±1.0 mV

Ammonium- Nitrogen:±5% of reading or 2 ppm, whichever is greater

Chloride:±5% of reading or 2 ppm, whichever is greater

Nitrate-Nitrogen:±5% of reading or 2 ppm, whichever is greater

Conductivity:±1% of reading or ±1 µS/cm, whichever is greater

TDS:±1% of reading or ±1 mg/L, whichever is greater

Salinity:±2% of reading or ±0.01 PSU, whichever is greater

Seawater σ:±1 σt, σ0, σ15

Turbidity:±0.3 FNU or ±2% of reading, whichever is greater

Dissolved Oxygen:0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm: ±1.5% of reading or 0.10 ppm, whichever is greater; 30.00 ppm to 50.00 ppm: ±3% of reading

Atm. Pressure:±3 mm Hg within ±15°C from the temperature during calibration

Temperature:±0.15°C; ±0.27°F; ±0.15K

Temperature Compensation:automatic from -5 to 55°C (23 to 131°F)

Logging Memory from Meter:44,000 records

Logging Interval: 1 second to 3 hours

Computer Interface:USB (with HI 929829 software)

FastTracker™ TAG ID:yes

Waterproof Protection:IP67

Environment: 0 to 50°C (32 to 122°F); RH 100%

Power Supply: 1.5V alkaline C cells (4) / 1.2V NiMH rechargeable C cells (4), USB, 12V power adapter

Dimensions: 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)

Weight :750g (26.5 oz.)


Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts