pH MEASUREMENT

pH Range:

-2.0 to 20.0 pH

-2.00 to 20.00 pH

-2.000 to 20.000 pH

pH Resolution:

0.1 pH

0.01 pH

0.001 pH

pH Accuracy:

±0.1 pH

±0.01 pH

±0.002 pH (±1 LSD)

ORP MEASUREMENT

ORP Range: ±2000 mV

ORP Resolution:

1 mV

0.1 mV

ORP Accuracy: ±0.2 mV ±1 LSD

Relative mV Offset: ±2000 mV

TEMPERATURE MEASUREMENT

Temperature Range:

-20.0 to 120.0 °C

-4.0 to 248.0 °F

253.0 to 393.0 K

Temperature Resolution: 0.1 °C / 0.1 °F / 0.1 K

Temperature Accuracy: ±0.2 °C / ±0.4 °F / ±0.2 K

ISE MEASUREMENT

Range: 1 × 10⁻⁶ to 9.99 × 10¹⁰ concentration

Resolution: 1; 0.1; 0.01; 0.001

Accuracy: ±0.5% (monovalent); ±1% (divalent)

Calibration: Automatic, up to 5-point calibration with 7 standard buffers and 5 custom standards

CONDUCTIVITY (EC) MEASUREMENT

EC Range:

0.000 to 9.999 µS/cm

10.00 to 99.99 µS/cm

100.0 to 999.9 µS/cm

1.000 to 9.999 mS/cm

10.00 to 99.99 mS/cm

100.0 to 1000.0 mS/cm

EC Resolution:

0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm;

0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm

EC Accuracy: ±1% of reading (±0.01 µS/cm)

EC Calibration

Mode: Automatic standard recognition / User-defined standard

1-point or multi-point calibration

Calibration points:

84.00 µS/cm, 1.413 mS/cm, 5.000 mS/cm,

12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm

Calibration reminder:

Off; Daily (0 min to 23 h 59 min);

Time-based (1 min to 500 days 23 h 59 min)

TOTAL DISSOLVED SOLIDS (TDS)

TDS Range:

0.000 to 9.999 ppm (mg/L)

10.00 to 99.99 ppm (mg/L)

100.0 to 999.9 ppm (mg/L)

1.000 to 9.999 ppt (g/L)

10.00 to 99.99 ppt (g/L)

100.0 to 400.0 ppt (g/L)

Actual TDS with factor 1.00

TDS Resolution:

0.001 ppm; 0.01 ppm; 0.1 ppm; 1 ppm;

0.001 ppt; 0.01 ppt; 0.1 ppt

TDS Accuracy: ±1% of reading (±0.01 ppm)

TDS Calibration:

Based on conductivity calibration

RESISTIVITY MEASUREMENT

Resistivity Range:

1.0 to 99.9 Ω·cm

100 to 999 Ω·cm

1.00 to 9.99 kΩ·cm

10.0 to 99.9 kΩ·cm

100 to 999 kΩ·cm

1.00 to 9.99 MΩ·cm

10.0 to 100.0 MΩ·cm

Resistivity Resolution:

0.1 Ω·cm; 1 Ω·cm;

0.01 kΩ·cm; 0.1 kΩ·cm; 1 kΩ·cm;

0.01 MΩ·cm; 0.1 MΩ·cm

Resistivity Accuracy: ±1% of reading (±1 Ω·cm)

Resistivity Calibration:

Based on conductivity calibration

SALINITY – NaCl

Range:

0.00 to 42.00 PSU – Practical Scale

0.00 to 80.00 ppt (g/L) – Natural Sea Water

0.0 to 400.0% – Percent Scale

Resolution:

0.01 for Practical Scale / Natural Sea Water

0.1% for Percent Scale

Accuracy: ±1% of reading

Calibration:

0.00 to 42.00 PSU: Based on conductivity calibration

0.00 to 80.00 ppt (g/L): Based on conductivity calibration

0.0 to 400.0%: 1-point calibration at 100% using HI7037 solution (sold separately)

DISSOLVED OXYGEN (DO)

DO Range:

0.00 to 90.00 mg/L (ppm)

0.0 to 600.0% saturation

NOTE: Instrument range is limited by the probe range

DO Resolution: 0.01 mg/L (ppm); 0.1% saturation

DO Accuracy: Depends on probe used

(HI7641133 – Optical DO probe or HI764833 – Polarographic DO probe)

BAROMETRIC PRESSURE

Range:

450 to 850 mmHg

600 to 1133.2 mBar

60 to 113.32 kPa

17.72 to 33.46 inHg

8.702 to 16.436 psi

0.5921 to 1.1184 atm

Resolution:

0.1 mmHg; 0.1 mBar; 0.01 kPa;

0.001 inHg; 0.001 psi; 0.0001 atm

Accuracy:

±3 mmHg ±15% of reading at calibration point

±3 mmHg ±1 LSD

Pressure Compensation: Automatic or manual

OTHER SPECIFICATIONS

Results Mode:

Direct; Direct/Autohold and Module

Stability: Accurate, medium, fast

DATA LOGGING

Type: Automatic, manual, autohold

Records:

Up to 50,000 records per file

Minimum 1,000,000 data points per user

Auto logging intervals:

1, 2, 5, 10, 30 sec;

1, 2, 5, 10, 15, 30, 60, 120, 150, 180 min

File format: .csv

CONNECTIVITY

USB-A: 2 ports for keyboard and/or printer or USB drive

USB-C: 1 port for PC connection and USB-C drive

Wi-Fi & Ethernet: Record transfer and download (web server; email; FTP)

RS232: Peripheral connection

CALIBRATION REMINDER

Daily: 0 min to 23 h 59 min

Periodic: 1 min to 30 days, 23 h, 59 min

Off

Users: Up to 9 users and 1 default admin account

POWER

100–240 VAC to 24 VDC 2A adapter

ENVERONMENT

0 – 50 °C / 32 – 122 °F / 273 – 323 K

Maximum 95% RH non-condensing

DIMENSIONS

205 × 160 × 77 mm (8.0 × 6.2 × 3.0 in)

WEIGHT

Approximately 1.2 kg

SUPPLIED WITH

HI6000-02 meter

HI764060 electrode holder

24 VDC power adapter

USB cable

Quick start guide

Datasheet


Manual

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts