HANNA BL982411-1 ORP Mini Controller (0 to 1000 mV)
USD 273.83
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available
| Range | 0 to 1000 mV | |
| Resolution | 1 mV | |
| Accuracy @ 25°C | ±5 mV | |
| Calibration | manual, with CAL trimmer | |
| Dosing Relay | maximum 2A (fuse protected), 250 Vac, 30 VDC | |
| Dosing Selection | reducing or oxidizing, selectable on the back panel contact open=reductant dosage=relay ON if measure > set point contact close=oxidant dosage=relay ON if measure < set point | |
| Setpoint | adjustable from 0 to 1000 mV | |
| Overtime | adjustable, typically from 5 to approx. 30 minutes | |
| Input Impedance | 102 Ohm | |
| Power Supply | See Chart | |
| Dimensions | 79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’) | |
| Weight | See Chart |