Gastec 12M Quick-measuring Detector tubes Hydrogen cyanide HCN (17~2400ppm)
ManufacturerGastec(View more products from this manufacturer)
Model12M
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available
Indicator: 50 to 800 ppm
Measuring Range:
+ 17 to 50 ppm, Number of Pump Strokes 2
+ 50 to 800 ppm, Number of Pump Strokes 1
+ 800 to 2400 ppm, Number of Pump Strokes 1/2
Sampling Time: 1 minutes per pump stroke
Colour Change: Yellow → Red
Reaction Principle: 2HCN + HgCl2 → Hg(CN)2 + 2HCl, HCl + Base → Chloride
Coefficient of Variation: 10% (for 50 to 200 ppm), 5% (for 200 to 800 ppm)
Nr. of tests: 10
Pump: GV-100S/110S
Performance
| Measuring Range |
|
|||
| Number of Pump Strokes |
|
|||
| Correction Factor |
|
|||
| Sampling Time | 1 minute per pump stroke | |||
| Detecting Limit | 1 ppm (n=2) | |||
| Colour Change | Yellow → Red | |||
| Reaction Principle | 2HCN + HgCl2 → Hg(CN)2 + 2HCl HCl + Base → Chloride |
|||
| Coefficient of Variation | 10% (for 50 to 200 ppm), 5% (for 200 to 800 ppm) | |||
| Shelf Life | 3 Years | |||
| Corrections for temperature & humidity | Unnecessary | |||
| Store the tubes at cool and dark place. | ||||
Possible coexisting substances and their interferences (NOTE)
| Substance | Concentration | Interference | Change colour by itself to |
| Hydrogen sulphide | 500 ppm | + | Red |
| sulphur dioxide | 500 ppm | + | Red |
| Calibration gas generation | Permeation tube method |
| TLV-TWA | TLV-STEL | Explosive range |
| - | C 4.7 ppm | 5.6 to 40% |