Digital I/O connector type: M12 12-pin A-coded, Male (shared with external power)

Digital Inputs: 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V

Digital Output Purpose: Programmatically set; fault (NC)

Digital Outputs: 3x: opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)

Encoding: GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric

Radiometric stream: Compressed JPEG-LS, FLIR radiometric

Ethernet Interface: Wired, Wi-Fi (optional)

WiFi: Optional feature purchased separately. RP-SMA, female connector

EMC: • ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery)

f-number: 1.4

Image Fequency: 30 Hz

Thermal Sensitivity/NETD: <35 mK

Accuracy: ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)

Alarm Function: NA

Alarm Output: NA

Communication & Data Storage

Digital I/O connector type: M12 12-pin A-coded, Male (shared with external power)

Digital I/O isolation voltage: 500 VRMS

Digital input purpose: NUC; NUC disable; image TAG (Start, Stop, General); image flow control (acc. SFNC 2.3): • Single frame (on trigg) • Multiframe (on trigg) • Continuous

Digital Inputs: 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V

Digital Output Purpose: Programmatically set; fault (NC)

Digital Outputs: 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)

Encoding: GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric

Ethernet: For control, result, image, and power

Ethernet Communication: • GigE Vision ver. 1.2 • Client API GenICam compliant • TCP/IP socket-based FLIR proprietary

Ethernet Connector Type: M12 8-pin X-coded, female; RP-SMA, female

Ethernet Interface: Wired, Wi-Fi (optional)

Ethernet Power: Power over Ethernet, PoE IEEE 802.3af class 3

Ethernet Protocols: • IEEE 1588 • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP, GVSP, GVCP

Ethernet Standard: IEEE 802.3

Ethernet Type: 1000 Mbps

Image Storage: NA

Multicast: Yes

ONVIF Profile S Compliant: No

RS-232: M8 A-coded, male connector

WiFi: Optional feature purchased separately. RP-SMA, female connector

Imaging & Optical

Contrast Enhancement: FSX® / Histogram equalization (IR only)

Detector Pitch: 17 µm

Field of view (FOV): 29° × 22°

f-number: 1.4

Focal Length: 14.3 mm (0.56 in)

Focal Plane Array (FPA): Uncooled microbolometer

Focus: Fixed, adjustable with included tool

Image Fequency: 30 Hz

IR Resolution: 464 × 348

Minimum Focus Distance: 0.25 m (0.82 ft)

MSX: Yes, included in visual camera option

Overlay: Without

Radiometric IR video streaming: RTSP protocol

Readout: No measurements readouts, only streamed video

Spectral Range: 7.5–14 µm

Streaming Resolution: GVSP video streaming: 640 × 480 pixels GVSP radiometric streaming: 464 × 348 pixels

Thermal Sensitivity/NETD: <35 mK

Video Streaming: GVSP (GigE Vision) protocol

Visible Camera: Optional accessory

Measurement & Analysis

Accuracy: ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)

Alarm Functions: NA

Alarm Output: NA

Atmospheric transmission correction: Based on inputs of distance, atmospheric temperature, and relative humidity

Automatic hot & cold detection: NA

Measurement Corrections: NA

Measurement Presets: NA

Measurement Tools: NA

Object Temperature Range: –20 to 175°C (–4 to 347°F) 175 to 1000°C (347 to 1832°F)

General

Base Mounting: 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate

Housing material: Aluminium

Size (L x W x H): 107 × 67 × 57 mm (4.21 × 2.64 × 2.24 in)

Weight: 519g (1.14lb) without bottom cooling plate

Humidity (Operating and Storage): IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles EN60068-2-38

Operating Temperature Range: –20 to 50°C (–4 to 122°F) Bottom cooling plate is needed in temperatures above 40°C (104°F). Maximum internal temperature sensor: 70°C (158°F)

Radio Spectrum: • FCC 47 CFR Part 15 Class C (2.4 GHz band US) • FCC 47 CFR Part 15 Class E (5 GHz band US) • RSS-247 (2.4 GHz and 5 GHz band Canada) • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU) • ETSI EN 301 893 V2.1.1 (5 GHz band EU)

Shock: IEC 60068-2-27, 25 g

Tripod Mounting: 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate

Vibration: • IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal • IEC 61373 Cat 1 (Railway)

Power

External Power Operation: 24/48 V DC 8 W max

External Voltage: Allowed range 18–56 V DC

Power Connection: M12 12-pin A-coded, male (shared with Digital I/O)

Power Consumption: • 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical