Cirrus research CR120A High-Performance Personal Noise Dosimeter (60 dB(A) ~ 140 dB(A); 80 dB(C) ~ 143 dB(C); 70 dB(A) ~ 140 dB(A))

Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Standards 

IEC 61252:1993 +AMD1:2000 Personal Sound Exposure Meters

IEC 61252 Ed 1.1 (2002-03) Personal Sound Exposure Meters

ANSI S1.25:1991 (R2017) Personal Noise Dosimeters

IEC 61260-1:2014 Class 2 (Octave Bands from 63Hz to 8kHz)

ANSI S1.11-2014 Class 2 (Octave Bands from 63Hz to 8kHz)

 

Measurement Range 

RMS Range – 60 dB(A) to 140 dB(A)

Peak Range – 80 dB(C) to 143 dB(C)

Octave Bands – 70 dB(A) to 140 dB(A)

 

Measurement Functions 

4 Simultaneous Independent Integrator Channels

2 Simultaneous Independent Peak Channels

1:1 Octave Bands (63Hz to 8kHz)


Overall Measurement Parameters 

Measurement duration, Start time & date, Instrument serial number & name

Calibration information (field & factory calibration), Overload & Tamper sensor detection


Overall Integrator Parameters 

Average Integrated Sound Level (Leq/LAVG), Time Weighted Average (LEP,d/LEX,8/TWA)

Sound Exposure & Estimated Sound Exposure, % Dose & Estimated % Dose, ULT Duration

SPL Max Level & Time, SPL Min Level

Overall Peak Channel Parameters

Overall LPeak level for each channel (Up to 2 channels)

Overall Octave Band Parameters

Overall unweighted Leq for each octave band (63Hz to 8kHz)

 

Communication 

Bluetooth® Wireless communication to the doseBadge5 dBControl

Bluetooth® Wireless communication to the dBLink App (Android & iOS)

USB download to NoiseTools via the doseBadge5 Dock


Integrator Channel Options 

Channel name – Preset or user defined

Exchange rate – 3, 4 or 5 dB

Criterion Level – 80 dB to 100 dB in 1 dB steps

Criterion Time – 1 hr to 24 hrs in 1hr steps

Threshold Level – None, 70 dB to 100 dB n 1dB steps

Time Weighting – Fast, Slow or None

Frequency Weighting – A, C or Z

ULT Level – 70 dB to 140 dB in 1 dB stepsULT Time Weighting – None, Fast or Slow

ULT Freq. Weighting – A,C, or ZSPL Max Time Weighting – Fast or Slow

SPL Max Freq Weighting – A,C or Z

LED Threshold Trigger – User selectable channel with user selectable % Dose trigger levels (75% to 100% in 5% steps)

 

Peak Channel Options 

Frequency weighting – A,C or Z (2 channels)

 

Calibration 

Automatic detection of external acoustic calibration

User configurable calibration level (typically 114dB or 94dB)

 

Data Logging 

1 second or 1-minute time history data (user selectable)


Memory 

Up to 80 hours of Time History Data for each channel including 1:1 Octave Bands

Up to 40 individual measurements

Maximum duration of any single measurement: 24 hours


doseBadge5 Dimensions 

66 mm x 43 mm x 53 mm (excluding clips)

2.53” x 1.69” x 2.01” (excluding clips) 85 g/2.9 oz

Datasheet


Manual

Stay Updated with Offers

Get exclusive volume discounts, bulk pricing updates, and new product alerts delivered directly to your inbox.

By subscribing, you agree to our Terms of Service and Privacy Policy.

Quick Support

Direct access to our certified experts