Frequency Range: 9kHz~4GHz

Tuning Resolution:1Hz

Frequency Reference

• Frequency: 10MHz

• Aging: ±0.5ppm/Year

• Initial Frequency Accuracy: ±0.3ppm

• Temperature Stability:±0.1ppm(-10~50℃, Comparative to 25℃)

Sweep Time

• Range: 10μs~600s (Zero Span)

• Accuracy: ±2.00% (Zero Span)

Frequency Readout Accuracy: ±(Frequency Readout× frequency Reference +2%× Span +10%× Resolution Bandwidth)

Frequency Span

• Range: 100Hz~Upper Frequency Limit of Corresponding Model or 0Hz

• Accuracy: ±2.0%

Resolution Bandwidth: 1Hz~10MHz (1-3 Times of Stepping)

Video Bandwidth: 1Hz~10MHz (1-3 Times of Stepping)

SSB Phase Noise(Carrier 1GHz)

≤-108dBc/Hz@ Frequency Offset 10kHz

≤-112dBc/Hz@ Frequency Offset 100kHz

≤-118dBc/Hz@ Frequency Offset 1MHz

≤-129dBc/Hz@ Frequency Offset 10MHz

Displayed Average Noise Level (input port is connected with a 50Ω load, 0dB input attenuation, average detection, logarithm of video type, RBW normalized to 1Hz, tracking source off, 20℃~30℃)

Pre-amp Off:

≤-140dBm(10MHz~3GHz)

≤-138dBm(3GHz~9GHz)

Pre-amp On:

≤-160dBm(10MHz~3GHz)

≤-157dBm(3GHz~9GHz)

Residual Response (exceptional frequency: 3.2GHz):

Pre-amp Off:

≤-82dBm(10MHz~9GHz)

Pre-amp On:

≤-95dBm(10MHz~9GHz)

Second Harmonic Distortion (0dB attenuation, -30dBm input signal): <-65dBc

Absolute Amplitude Accuracy (input signal 0dBm~-50dBm, all settings are automatic couplings, 20℃~30℃, 30 minutes of preheating)

±1.8dB (10MHz~13GHz)

±2.3dB (13GHz~40GHz)

±2.7dB (40GHz~50GHz)

±3.0dB (50GHz~67GHz)

Input Attenuator: Attenuation Range: 0dB~30dB, 5dB Stepping

Maximum Continuous Input:

+27dBm Peak Typical(≥10dB Attenuation)

+20dBm Peak Typical(<10dB Attenuation)

+10dBm Peak Typical(Pre-amp On)

Reference Level: Range: -120dBm~+30dBm; Conversion Uncertainty: ±1.20dB

Dimension

• 314mm (W)×218mm (H)×91mm (D) (Excluding Handle, Stand)

• 338mm(W)×218mm (H)×100mm (D) (Including Handle, Stand)

Weight: ≤4.5kg

Working Temperature: -10℃~+50℃ (the battery operation temperature is 0℃~+45℃)

Storage Temperature: -40℃~+70℃ (the battery storage temperature is -20℃~+60℃)

Electromagnetic Compatibility: Conforms to GJB3947A-2009 3.9.1 Requirements

Battery operation time: about 3h

Power Consumption: ≤25W

Test Interface:

• RF input: Type-N Connector(female)

• RF output: Test interface of tracking generator option for 4024A/B/C: Type-N Connector(female)

Other Interfaces

• 10MHz Reference Input/Output: BNC (female) Connector

• External Triggering Input: BNC (female) Connector

• IF Output: BNC (female) Connector

• GPS Antenna Input: BNC (female) Connector