Product image

Auto ELISA Processor BIOBASE BIOBASE2000

ModelBIOBASE2000
OriginChina
Warranty12 months
Contact
Secure Checkout
Quality Engagement
Easy change and return
Delivery Available

Manufacturer: BIOBASE

Model: BIOBASE2000

Origin: China

Warranty: 12 months

Features:

- 4 microplates,2 pipetting probes

- 192 sample positions , 96 dilution positions,23 reagent positions, 16 common reagent positions,48 QC positions.

- All sample & reagent positions can be editable.

Sample pipetting unit

Sample rack: 24 sample tubes/rack, at most 23 racks

Primary sample tubes: 11.5-13mm

Pipetting: 8ul~1000ul, (10ul) CV<5%

Time to dispense: 12 minutes adding 96 samples

Dispensing system: 1 aspirating-dispensing probe with X-Y-Z movement;dilution system with a syringe of 1000ul, continuous flow washing station.

Reagent pipetting unit

Reagent racks: 2 reagent tanks(60ml)/ rack, at most 23 racks

QC racks: 24 positions/QC rack, at most 23 racks

Pipetting : 8ul~1000ul,1ul stepping

pipetting precision: (100ul )CV≤0.5%

Time to dispense: 3 minutes(typical)^100ul of 96 reagents to plate from reagent bottle

Programmable: Yes(options & parameters)

Wash containers: 3 wash buffers at 2.0L,1 wash buffers at 5.0L,with level-sensing

Waste containers: 25L with waste full sensor

Washing system: two 8 nozzle manifolds, one to dispense and the other one to aspirate

Washing residual: <2μl

Reading system: 8 independent photometric channels with mono and bichromatic reading capability

Photometric range: 0.000 ~3.000 OD

Spectral range: 400-700nm

Optical filters: 2 precision filters (450and 630nm); 2 more on request (4 filters max, 405 nm, 450 nm, 492 nm and 630 nm)

Reading inaccuracy: inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD

Incubators: 4 independent units

Programmable: Yes

Temperature range: RT to 45 °C

Temperature accuracy: ±0.5℃

Temperature staility: ±0.5℃

Software system: Windows 7/8/107 or above, LIS system available

Function application: work list set up, patient reports and result filing; calibration curve storage for each carried out test

Data reduction: cut-off (qualitative)

Power Supply: AC 110/220V±10%,50/60Hz,450W

External Size(W*D*H): 1235*710*880mm

PackageSize(W*D*H): 1370*850*1439mm

Gross Weight: 220kg