Input

Input range: 90 - 264 Vac; 127 - 300 Vdc

Frequency: 47 - 63 Hz

Inrush current: 50 A max., cold start @ 25°C

Efficiency: 82% typical at full load

EMI/RFI: FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted

Safety ground leakage current: 275 µA @ 50/60 Hz, 264 Vac input

Output

Maximum power: 130 W with 200 LFM forced air

Adjustment range: All outputs adjustable: -20%, +10%, except for +24V output on LPT104-M which will be -10%, +20% and 3.3 V output on the LPT101- M +10%, -15%

Hold-up time: 10 ms @ 130 W load, 120 Vac input

Overload protection: Short circuit protection on all outputs. Case overload protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3

Overvoltage protection: 15 - 35% above nominal output

Logical Control

Power failure: Active LowTTL logic signal goes high 100 - 500 msec after main output; it goes low at least 6 msec before loss of regulation

Remote sense: Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected

Environmental Specifications

Operating temperature: 0°C to 50°C ambient derate each output as 2.5% per degree from 50 °C to 70 °C. -20°C start up

Storage temperature: -40°C to +85°C

Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3

Humidity: Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95%

Vibration: IEC68-2-6 to the levels of IEC721-3-2

MTBF calculated: 583.000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore

Ordering Information

Output: Triple

1.

Output Voltage: +5 V

Minimum Load: 0 A

Maximum Load with 30CFM Forced Air: 18 A

Peak Load: 20 A

Peak Load: ±2%

Ripple P/P (PARD): 50 mV

2.

Output Voltage: +15 V

Minimum Load: 0 A

Maximum Load with 30CFM Forced Air: 17.2 A

Peak Load: 8 A

Peak Load: ±5%

Ripple P/P (PARD): 150 mV

3.

Output Voltage: -15 V

Minimum Load: 0 A

Maximum Load with 30CFM Forced Air: 1.5 A

Peak Load: 2 A

Peak Load: ±5%

Ripple P/P (PARD): 150 mV