ACW
+ Out voltage range: 500~3000VAC,10V/step, ±(2.5%×setting+10V)
+ Output frequency: 50/60Hz, ±0.1%×Setting
+ Breakdown current range: 0.100~20.00 mA, ±(2.5%×reading+5 counts)
IR
+ Output voltage range: 500~3000VAC,100V/step; ±5%×setting
+ Energy capatitor:Standard 0.255uH
+ Sampling frequency:50kHz~40MHz,15 adjustemnt range
+ Test time:1~10 times continuous
IW
+ Pulse voltage range: 500~3000VAC,100V/step; ±5%×setting
+ Energy capatitor:Standard 0.022uH
+ Sampling frequency: 50kHz~40MHz,15 adjustment range
Weight: 33 kg

 

Product Detail

Main features
* Wingding reverse:Check if the stators winding is reversed
* Multi-Channel:Provide 8 channels configuration to 2 station mode,16 channels configuration to single station mode
* Large ACW capacity:Standard is 3KV/20mA,but can be up to 5KV/100mA
* Large IW capacity:IW is improved to 0.1uF storage capatitor,strongger identification
* Modify ACW mode:Case Hight voltage,wire high voltage and phase to phase mode.

Application
Suitable to test the stator of Y/△ type 3 phase motor,Single phase motor,Brushless motor,Car alternator motor, Synchronous motr,Multi-speed motro.

Accessories
* Connection fixture
Clamp,terminals,probe(elastic and unelastic type)
*Start control mode
Button on test bench,protection cover,barcode,remote box,foot pedel
* Return terminal accessories V groove,circle bridge,metal board,self-priming return teminals

Model

AN96951(F)

AN96950(F)

AN9653(F)

ACW

Out voltage range:500~3000VAC,10V/step.(5000V can be modified)

Voltage accuracy:±2.5%×setting+10V Output frequency:50/60Hz

Frequency accuracy:±0.1%×setting

Breakdown current range:0.100~20.00 mA(100Ma can be modified)

Current accuracy:±2.5%×reading+5 counts

IR

Output voltage range:500~3000VAC,100V/step.(5000V can be modified)

Voltage peak accuracy:±5%×setting

Energy capatitor:Standard 0.255uH,0.047uH is optinal

Front time of impulse:0.5uS

Sampling frequency:50kHz~40MHz,15 adjustemnt range

Test time:1~10 times continuous

Ajustment:Area,differ

IW

Pulse voltage range:500~3000VAC,100V/step.(5000V can be modified)

Voltage peak accuracy:±5%×setting

Energy capatitor:Standard 0.022uH,0.047uH is optinal

Front time of impulse:0.5us

Sampling frequency:50kHz~40MHz,15 adjustment range

Test time:1~10 times continuous

Ajustemnts:Area,differ

DCR

----

Range:0.020~0.200~2.000~20.00~200.0~2000~20000Ω

Accuracy:±0.3%×reading + 3 counts

---

Power/Voltage start

---

Voltage range:

20~300V,10V/step.

Accuracy:±0.3%×reading +0.2%×range

Current range:

0.20~2.00~20.00A

Accuracy:±0.3%×reading + 0.2%×range

Active pwer range:

1.0~99.9W~6KW

Accuracy:±0.8%×reading +0.2%×range

Frequency range:45~500Hz

Accuracy:± 0.1% ×reading

Voltage range:

20~460V,10V/step.

Accuracy:±0.3%×reading +0.2% ×range

Current range:

0.05~6.00~40.00A

(100Ma can be modified)

Accuracy:±0.3%×reading + 0.2% range

Active pwer range:

1.0~99.9W~18kW

Accuracy:±0.8%×reading +0.2×range

Frequency range:45~65Hz

Accuracy:±0.1%×reading

C voltage

---

Voltage range:60.0~600.0V

Accuracy:±0.6%×reading

---

Speed

---

Range:120~99,999rpm

Accuracy:±0.1%×reading+1

---

Rotation

---

RW/RS/RI/KEEP

---

PG single

---

PG power:5V or 12V

Voltage test:0.50~15.0V

Accuracy:±0.5×reading +2 counts

Frequece range:10~1000Hz

Accuracy:±0.1%×reading+1 count

---

Weight(without packaging)

33Kg

 

 