Power [kW]: ±400

Output Voltage [V]: 12-1200

Output Current [A]: ±800

Size (WHD) [mm]: 2010x1955x1200

Weight [kg]: 2470

Basic Parameters

Output mode: CV, CC, CP, programming and PV standard (EN50530\Sandia) dynamic & static MPPT tracking, PV array

Energy feedback: Receive load energy and feed it back to the grid

Isolation function: Electrical isolation of input and output

Parallel function: Multiple sets of the same model can be connected in parallel

DC output

Voltage

Resolution(V): 0.01

Accuracy: ±0.1% F.S.

Effective ripple value: 0.1% F.S (resistive load)

Voltage slew rate: 200V/ms

Current

Resolution (A): 0.01

Accuracy: ±0.1% F.S.

Effective ripple value: 0.2% F.S. (resistive load)

Rise time: 2.5 ms (10%-90% rated current)

Switching time: 5ms (switching from -90% to +90%)

I-V Curve

Open-circuit voltage

setting range: 12~1200V

Short-circuit current setting range: 1A~Ie

Simulation fill factor range: 0.3~0.95

Photovoltaic panel type: c-si, Thin-film, user-defined

I-V curve update rate: 100ms with online curve switching function

I-V curve editing: EN 50530, Sandia, and simple with user-defined curves; static MPPT curves; dynamic MPPT curves; shadow barrier; curve programming

Number of points on a single curve: 4096 points

Curve setting

1) IV curves can be user-defined using parameters such as Voc, Isc, FF and Pm;

2) The I-V curve database is provided, with the number of curves ≥ 100;

3) IV curves in different situations can be continuously output in the dynamic operating modewith the environmental impacts such as temperature change and irradiance 4) The dynamic I-V curve test program under EN50530 is built-in;

Universal programmable

Programming steps: 200 steps

Programming parameters: Voltage/current, rise time, hold time, trigger pulse output

Rise time range: 1ms-99999s

Flat top time range: 1ms-99999s

Minimum programming time step: 1ms

Editing mode: Add, delete, import, export

Operation mode: Run, stop, loop

Trigger mode: Automatic, manual, external

Measurement

Voltage accuracy: ±0.1% F.S.

Voltage resolution (V): 0.001

Current accuracy: ±0.1% F.S.

Current resolution (A): 0.001

Power accuracy: ±0.2% F.S.

Power resolution (kW): 0.001

AC input

Wiring mode: Three-phase four-wire ABC+PE

Frequency (HZ): 47 - 63

Voltage range (V): 380V±15%

Power factor: 0.99 @ full load

Efficiency: Models of 300kW and above: > 94%; Others: > 90%

Harmonic current: ≤3%

Other Parameters

Protection function: OVP, OCP, OPP, OTP, Phase loss protection Communication interface: Standard configuration: LAN; optional: RS485, CAN

External interlocking: External interlocking input is normally on/off; external interlocking output is normally on/off. Trigger signal Trigger input/output

Control and display: Local touch screen control and remote computer control; display voltage, current, power andoperation trend chart

Insulation and withstanding voltage: 10MΩ/DC500V;3600VAC(5000VDC)/1min

Cooling mode: Fan cooling

Operating temperature: -10℃~40℃

Relative humidity: 10% to 90% RAH

Altitude: ≤2000m