Output Power [kVA]: 600

Voltage Range [V] @ L-N: 0-860

Frequency Range [Hz]: 40-70

Max. Current [A] @ 3 phase: 572

Size (WHD) [mm]: 3400x1950x1200

Weight [kg]: 3670

AC Output Voltage

Accuracy: ±0.1% F.S.

Resolution: 0.01V

Load Regulation : ±0.05% F.S. @ Linear load

Line Regulation: ±0.05% F.S. @10% Voltage

Slew Rate: AC>1.0V/us

Response Time: <1ms (10%-90%Umax)

Voltage Distortion:

+ Less than 0.5% @50Hz/60Hz ≥ 220V for no-load

+ Less than 1% @50Hz/60Hz ≥ 220V for linear load

+ Less than 1.0% @ other frequency ≥ 220V for no-load

+ Less than 1.5% @ other frequency ≥ 220V for linear load

AC Output Current

Accuracy: ±0.2% F.S.

Resolution: 0.01V

Output Frequency

Accuracy: ±0.01%

Resolution: 0.001Hz

Range: 40-70Hz

Phase Angle Control

Accuracy: ±0.3°

Resolution: ±0.1°

Phase Angle Range : 0 - 359.9°

Phase Control: Single-phase, Three-phase, Three-phase independent

Voltage Ride Through

Mode: ZVRT / LVRT / HVRT

Setting Parameter :voltage, frequency, phase, rise time, hold time, trigger phase angle and pulse output

Harmonic Injection

Order: 50th@50Hz/60Hz

Content:

+ Max 40% for 2-10 single harmonics, less than 40% for 2-10 total harmonics

+ Max 20% for 10-20 single harmonics, less than 20% for 10-20 total harmonics

+ Max 10% for 21-30 single harmonics, and no more than 10% for total harmonics

+ Max 5% for 31-50 single harmonics, and no more than 5% for total harmonics

+ It can simultaneously synthesis 49 harmonics

Amplitude Error: ±5% harmonic of set value

Preview Function: Harmonic synthesis waveform can be previewed

Editing Mode: import, export, read, storage

Inter Harmonic:

Frequency Range : 1Hz-3,000Hz, content <10%

Programming Steps: 100 steps

Programming Parameters: content, start frequency, end frequency, step length, execution time, interval time, cycle times and sequence

Editing Mode: add, delete, import, export, store, read

Flicker

Flicker Level: 1.0-10.0. totally 10 levels in total, and one-key calling

Adjustment Step Length : 1

Accuracy: ±0.2

Preview Function: Preview of flicker trend chart, pst can be visualized

Resolution: 0.01V

Three-phase Unbalance

Adjustment Mode: three-phase voltage, single phase; unbalance factor

Unbalance Factor Range (%) : 1~100

Unbalance Factor Step Length (%) : 1

Accuracy (%) ±0.5%

Preview Function : three-phase unbalance trend chart can be previewed

Measurement

Voltage Accuracy: ±0.1% F.S.

Frequency Accuracy: ±0.01%

Current Accuracy: ±0.2% F.S.

Active Power Accuracy: ±0.3% F.S.

Apparent Power Accuracy: ±0.3% F.S.